Simple radiated emission measurement

Low cost and simple radiated emission measurement by spectrum / signal analyzer and biconical antenna.

[Application]

If the environmental noise is sufficiently smaller than the radiated emission limit level, it is possible to perform simple radiated emission measurement even in a normal laboratory.

[Solution]

The radiated emission from the EUT is extracted by subtracting the measured value at EUT OFF (environmental noise) from the measured value at EUT ON.
(It is necessary to calculate after converting the unit to [uV / m] of linear rather than [dBuV / m] of logarithm, when subtracting.)

Figure:Simple radiated emission measurement

[System configuration]

Signal analyzer [MSA538E]
Biconical Antenna [MAN150]
Jigs to mount antenna and EUT
Others(PC, I/F modules, cables, etc)

*We will propose specifications that meet your needs.
*MICRONIX Corporation reserves the right to make changes in design, specification and other information without prior notice.